SAMPLE — NOT FOR JOBSITE USE
Energized diagnostics JHA Example
This educational electrical example is generated from source-mapped clause bank version 2026.08.28-ai3.
| Clause | Control | Citation |
|---|---|---|
| CTL-ELEC-002 | Controls to be deactivated during work on energized or deenergized equipment or circuits shall be tagged; deenergized equipment or circuits shall be rendered inoperative and shall have tags attached at all points where they can be energized, and tags shall be placed to identify plainly the equipment or circuits being worked on. | 29 CFR 1926.417(a); 29 CFR 1926.417(b); 29 CFR 1926.417(c) |
| CTL-ARC-001 (recommended practice) | Before work on or near equipment presenting an arc-flash hazard, the employer should assess the hazard and ensure exposed employees use protective equipment appropriate to the parts of the body exposed, including arc-rated clothing, face and eye protection, and insulated tools and gloves. Construction Subpart K sets no pre-work arc-flash assessment duty; arc-flash-specific requirements appear in Subpart V for power transmission and distribution work by qualified employees. | Recommended practice NFPA 70E; Standard for Electrical Safety in the Workplace; OSH Act Section 5(a)(1) |
| CTL-ELEC-001 | No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means. | 29 CFR 1926.416(a)(1) |
| CTL-ELEC-003 | All 120-volt, single-phase, 15- and 20-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by employees shall have approved ground-fault circuit interrupters for personnel protection, or the employer shall establish and implement an assured equipment grounding conductor program. | 29 CFR 1926.404(b)(1)(ii); 29 CFR 1926.404(b)(1)(iii) |